{"product_id":"mya-5-5y-f-a-microbalance-for-filter-weighing","title":"MYA 5.5Y.F.A Microbalance for Filter Weighing","description":"\u003ch2\u003e\n\u003cstrong\u003eMYA 5.5Y.F.A Microbalance\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobalances for filters\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eare \u003cstrong\u003ehigh-precision laboratory balances\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003edesigned for\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eaccurate filter weighing\u003c\/strong\u003e in analytical, pharmaceutical, environmental and many other laboratories. With ultra-precise mechanisms and state-of-the-art technology,\u003cbr\u003ethese \u003cstrong\u003emicrobalances \u003c\/strong\u003eprovide reliable results essential for research and control processes.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eHigh Precision\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMicrobalances for filters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide exceptional measurement accuracy crucial during quantitative and qualitative analysis of samples. They can weigh with microgram readability, allowing precise monitoring of filter mass before and after analysis.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eHigh-tech\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicrobalances for filters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide stable and repeatable results. State-of-the-art measuring systems minimize the influence of ambient conditions on weighing results.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEnvironmental Laboratories\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eAir, water and soil quality analysis requires precise filter weighing used to collect samples. Microbalances for filters are an indispensable tool in such research.\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePharmaceutical Industry\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eIn production and control processes in the pharmaceutical industry, weighing accuracy is crucial. Microbalances provide the necessary precision for process monitoring.\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eScientific Research\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eIn research laboratories where advanced studies of new materials, chemicals or biological processes are conducted, microbalances for filters provide the dependability and accuracy needed for reliable results.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eDo you need a balance that not only determines weight with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003eIf so, learn about the functionality of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eELLIPSIS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries of balances:\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eDigital Weighing Auditor\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eEnsures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003e10-Inch Display\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eBigger screen – 10’’ – means more information in one place. On the new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eELLIPSIS terminal\u003c\/strong\u003e, you will see up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 screens\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewidgets\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egraphs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatuses\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enotes\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehandy measurement history\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eUncompromising User Verification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eFor the first time ever, the balance will verify the user using a \u003cstrong\u003epassword\u003c\/strong\u003e,\u003cbr\u003e\u003cstrong\u003eRFID card\u003c\/strong\u003e, \u003cstrong\u003efingerprint reader\u003c\/strong\u003e, \u003cstrong\u003efacial recognition mechanism\u003c\/strong\u003e, or \u003cstrong\u003eany combination of these\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eAmbient Light – An Innovative Way for the Balance to Communicate With the User\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe light colour will tell you about status, process results, procedures, or alerts.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eHotspot\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eUse the balance on any device connected to it. This can be a smartphone, tablet, or computer.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eRFID\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eELLIPSIS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eworks with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRFID tags\u003c\/strong\u003e* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eLive Note – Note Down Your Conclusions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eIt’s the first time you can add a text memo to a measurement series or procedure report. These can be, for example, assumptions, reminders or questions that can be returned to at any time.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eHandy Library\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThis is where a series of recent measurements or a report ready for digital signature, according to \u003cstrong\u003e21 CFR Part 11\u003c\/strong\u003e, can be found.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eWidgets\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003ePrepared to display what you need most at any given moment.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eAutomatic Leveling of the Balance ReflexLEVEL System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eInstead of manually leveling your scale - level it automatically.\u003cbr\u003eThe \u003cstrong\u003eReflexLEVEL System\u003c\/strong\u003e saves you time and gives you maximum precision\u003cbr\u003ein your measurements.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eSmart Min Weight\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eDo you work in the pharmaceutical industry? Do you need a digital signature?\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eWe are offering the laboratory balance which as a standalone fully meets the requirements of \u003cstrong\u003e21 CFR Part 11\/ EU GMP Annex 11\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e- Full data security\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e- Electronic signatures\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e- Validations\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e- Electronic records\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e- Audit trails\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eModbus TCP\/IP\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eis one of the most popular communication protocols in industrial automation. Implementing it in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5Y balances and CY10 scales\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emakes the devices of this series friendly to automation integrators. \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eA balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProtocol Modbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 5Y balances and C10 scales enables, among other things, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erealization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eTwo-point adjustment\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eAdjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMetrological Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacity [Max]\u003c\/td\u003e\n\u003ctd\u003e5.1 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadability [d]\u003c\/td\u003e\n\u003ctd\u003e1 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVerification Unit [e]\u003c\/td\u003e\n\u003ctd\u003e1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTare Range\u003c\/td\u003e\n\u003ctd\u003e-5.1 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Repeatability [5% Max]\u003c\/td\u003e\n\u003ctd\u003e0.6 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Repeatability [Max]\u003c\/td\u003e\n\u003ctd\u003e1.6 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Minimum Weight (USP)\u003c\/td\u003e\n\u003ctd\u003e1.2 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Minimum Weight (U=1%, k=2)\u003c\/td\u003e\n\u003ctd\u003e0.12 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Repeatability [5% Max]\u003c\/td\u003e\n\u003ctd\u003e1.2 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Repeatability [Max]\u003c\/td\u003e\n\u003ctd\u003e2.4 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±5 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEccentric Load Deviation\u003c\/td\u003e\n\u003ctd\u003e5 µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity Time Drift\u003c\/td\u003e\n\u003ctd\u003e1×10⁻⁶ \/ Year × Rt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003eMax 8 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment\u003c\/td\u003e\n\u003ctd\u003eInternal (automatic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOIML Class\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePhysical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeveling System\u003c\/td\u003e\n\u003ctd\u003eAutomatic – Reflex Level System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10″ Graphic Colour Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighing Chamber Doors\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighing Pan Dimensions\u003c\/td\u003e\n\u003ctd\u003eø70 + ø16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighing Chamber Dimensions\u003c\/td\u003e\n\u003ctd\u003eø93.8×35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery Components\u003c\/td\u003e\n\u003ctd\u003eMicrobalance, terminal, weighing pan, weighing pan for filters, centring ring, glass lid, power supply, pincette, brush, fabric dust cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Dimensions\u003c\/td\u003e\n\u003ctd\u003e750×492×595 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e10.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP 43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eCommunication Interface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi®, Hotspot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eElectrical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply (Adapter)\u003c\/td\u003e\n\u003ctd\u003e100–240V AC 50\/60Hz 1A; 15V DC 2.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalance Supply\u003c\/td\u003e\n\u003ctd\u003e12–15V DC 1.4A max*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironmental Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+10 – +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Change Rate\u003c\/td\u003e\n\u003ctd\u003e±0.3 °C \/ 1 h (±1 °C \/ 8 h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e40% – 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Change Rate\u003c\/td\u003e\n\u003ctd\u003e±1% \/ h (±4% \/ 8 h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eWi-Fi\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eis a registered trademark of Wi-Fi Alliance\u003csup\u003e®\u003c\/sup\u003e.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis expressed as a standard deviation from 10 cycles of mass standard weighing.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStabilization time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edependson the ambient conditions and the dynamics of weighing pan loading; specified for FAST profile.\u003c\/div\u003e\n\u003cdiv\u003e* The power supply can be connected to the socket on the back of the balance housing or to the terminal.\u003c\/div\u003e","brand":"Gravitation Ltd","offers":[{"title":"Default Title","offer_id":68001048985917,"sku":"WL-109-0024","price":14407.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1023\/4540\/8829\/files\/5Y-7.jpg?v=1794190488","url":"https:\/\/shopzenvoria.shop\/products\/mya-5-5y-f-a-microbalance-for-filter-weighing","provider":"Ashwell \u0026 Co.","version":"1.0","type":"link"}